  Watt Rating/ Class of Coil Insulation 

  Electrical Check Breaker Roughing

  Foreline or High Vacuum

  Suction or ReleaseMin. Max. AC Catalog Number Catalog Number AC NORMALLY CLOSED

  (Closed when de-energized) 1/4 9/32 0.96 0 15 Brass      180 8262G090VM 8262G090VH

  1 6.1/F 3/8 3/8 1.8 0 15 Brass      180 8030G013VM 8030G013VH 2 10.1/F 1/2 7/16 2.8 0 15

  Brass      180 8030G017VM 8030G017VH 3 16.1/F 3/4 3/4 5 0 4 Brass  - -

  - - 180 8030G043VM 8030G043VH 4 17.1/F 3/4 3/4 5 0 15 Brass -  - - 

  Const. Ref.

  Nominal Ambient Temp. Ranges 32?F to 125?F (0?C to 52?C) Refer to Engineering Section for details.

  Approvals CSA certified. Meets applicable CE directives. Refer to Engineering Section for details.

  Standard: Watertight, Types 1, 2, 3, 3S, 4, and 4X. Optional: Explosionproof and Watertight,

  Specifications (English units)

  Pipe Size (ins.)

  Orifice Size (ins.)

  Cv Flow Factor

  Operating Pressure Differential (psi)

  Body Material

  Application Guide Max. Fluid Temp. ?F

  180 8210G095VM 8210G095VH 5 10.1/F 1 1 5/8 20.5 0 15 Alum. -  - - 

  125 8215G050VM  8215G050VH  8 16.1/F 1 1/4 1 5/8 31.7 0 15 Alum. -

   - -  125 8215G060VM  8215G060VH  8 16.1/F 1 1/2 1 5/8 32.7 0 15 Alum.

  -  - -  125 8215G070VM  8215G070VH  9 16.1/F 2 2 3/32 55 0 15 Alum. - 

  - -  125 8215G080VM  8215G080VH  10 16.1/F NORMALLY OPEN (Open when de-energized)

  3/8 5/8 3 0 15 Brass -  - -  180 8210G033VM 8210G033VH 6 10.1/F 1/2 5/8 4 0 15 Brass -  -

  -  180 8210G034VM 8210G034VH 6 10.1/F 3/4 3/4 5.5 0 15 Brass -  -

  -  180 8210G035VM 8210G035VH 7 10.1/F 1 1 5/8 20.5 0 15 Alum. -  -

  Conditions Pressure Low (and Rough) 760 to 25 Torr (or 29" Hg)

  Medium (and Fine) 25 to 10-3 Torr High 10-3 to 10-6

  Torr Very High 10-6 to 10-9 Torr Ultra High 10-9 Torr and Below

  Standard Coil and Class of Insulation

  Watt Rating and Power Consumption Spare Coil Part No. AC General Purpose Explosionproof

  VA Inrush AC AC F 6.1 238214 F 10.1 25 70 238610 238614 F 16.1 35

  272614 F 17.1 40 93 238610 238614 Standard Voltages: 24, 120, 240, 480 volts AC, 60 Hz

  (or 110, 220 volts AC, 50 Hz). Must be specified when ordering. Other voltages,

  including DC, available when required.  - -  125 8215G073VM  8215G073VH  12 16.1/F 2 2 3/32 55 0 15 Alum. -

   - -  125 8215G083VM  8215G083VH  13 16.1/F  Valves must be mounted with solenoid vertical and upright. 

  On 50 hertz service, the rating for the 6.1/F solenoid is 8.1 watts.  For low vacuum applications to 29" Hg,

  use standard catalog valves with 0 psi minimum, 15+ psi maxium OPD (except 2" NPT).

  Solenoid Valves for Low, Medium, and High Vacuum Service Brass or Aluminum Bodies 1/4" to 2" NPT

  Solenoid Enclosures

  -  125 8215G053VM  8215G053VH  11 16.1/F 1 1/4 1 5/8 31.7 0 15 Alum. - 

  - -  125 8215G063VM  8215G063VH  11 16.1/F 1 1/2 1 5/8 32.7 0 15 Alum. -

  Types 3, 3S, 4, 4X, 6, 6P, 7, and 9. (To order, add prefix “EF” to catalog number.)

  See Optional Features Section for other available options.

  SPECIAL SERVICE VALVES

  Features ? Range of products for vacuum service applications on vacuum breaking and roughing pumps

  ? Zero Minimum Operating Pressure Differential ? Elastomers de-gassed and cleaned ("VH" suffix)

  ? Mountable in any position, except as notedMedium Vacuum to 10-3 Torr 

  High Vacuum to 10-6 Torr 