电 话:021-39526589-8004
联系人:余玲
手 机:17302157802
地 址: 中国 上海 嘉定区嘉涌路99弄6号713
更新时间:2022-11-18 浏览数:37
所属行业:仪器仪表> 流量仪表> 其他流量仪表
发货地址:
产品规格:--
产品数量:1
包装说明:--
单 价:面议
德国进口burkert流量控制器选型样本
上海乾拓贸易有限公司
电话:-8004
手机:(微信)
邮箱:@163.com
企业qq:2880626084
联系人:杨江玲
地址:上海嘉定区嘉涌路99弄6号楼713室。
food and beverage industry, environmental technology, material coatings, fuel cell technology or test benches.
nominal flow ranges from 20 ln/min up to 1500 ln/min
high accuracy and repeatability
socket m16, round, 8 pin and socket d-sub hd15, 15 pin
socket m12 5 pin or d-sub 9 pin plug m12 5 pin or d-sub 9 pin plug d-sub 9 pin
operating voltage 24 v dc voltage tolerance ± 10 % residual ripple < 2 % power consumption 12.5 w–37 w
the integrated pi controller ensures outstanding control characteristics of the mfc. type 8626 can optionally be calibrated
? high accuracy and repeatability ? short settling times
total weight (examples) 2.5 kg (al, 16 w-valve) 4.5 kg (va, 16 w-valve) mounting position horizontal
or vertical light emitting diodes (default, other functions programmable) indication for 1. power, 3. limit 2. communication 4. error
short settling times
the mass flow controller (mfc) type 8626 is suited for regulating the mass flow of high gas flows.
< 500 ms materials body housing seals aluminium (black anodized) or stainless steel aluminium (coated) fkm, epdm
port connection g ?", ?", ?", ?", 1" npt ?", ?", ?", ?", 1" control valve valve
ori? ce kvs value normally closed 0.8…12 mm 0.02…2.8 m3/h electr. connection
additionally with: -profibus-dp: -canopen: with rs485 version only:
optional: fieldbus interface
nominal flow ranges from 20 ln/min up to 2500 ln/min
(depending on version) type of protection (with connected cables) ip65 dimensions see drawings on p. 6–9
the thermal inline sensor is located directly in the gas stream and therefore reaches very fast response times.
a direct-acting proportional valve from bürkert guarantees a high sensitivity.
? protection class ip65 ? optional: fieldbus interface
nominal ? ow range1) (qnom)
20…1500 ln/min2), n2 equivalent see table on page 2, higher ? ows on request turn-down ratio 1:50 3)
operating gas neutral, non-contaminated gases, others available on request calibration gas operating gas
or air with correcting function max. operating pressure (inlet pressure) up to max. 10 bar,
for two different gases; the user can switch between these two gases. as electrical interfaces both,
analog standard signals and fieldbuses are available. the mass flow controller type 8626 is especially designed for
use in harsh environments due to a low sensitivity to contamination and the high protection class.
the mfc fits for various applications, like e.g. burner controls, heat treatment, llurgy,
protection class ip65
depending on the ori? ce of the valve gas temperature - 10 to + 70 °c (- 10 to + 60 °c with oxygen)
ambient temperature - 10 to + 45 °c (higher temperatures on request) accuracy (after 15 min warm up time)
± 1.5 % o.r. ± 0.3 % f.s. (o.r.: of reading; f.s.: of full scale) repeatability ± 0.1 % f.s. settling time (t95 %)德国进口burkert流量控制器选型样本